This is a Thyristor Based Normally Open 230V Switch that can be turned on / off at a fast rate. This switches at Zero Crossover .Built In Snubber reduces EMI and protects the SSR. USE SAME PHASE FOR I/P & O/P.
Notes -
The Termination's of High Current Lines going to Load must be very tight and crimped. Loose contacts will Spark and cause Fire.
Web
Enabled 4-20 mA Input Controller
Fuse Rating of HRC Fuse - High Rupture Capacity (HRC) Fuse is
Safe and Reliable. 5kW Heater at 230V is 5,000 / 230 in Amps
of Fuse Rating.
Connection Diagram of SSR DC 3-30 Control / 230V AC N.O.
Use 12V DC for Best Results. This one is DC 3-30 Control AC
230V N.O. Output. Rest same as above.
Diagram of SSR 5000 DC 3-30 Control / 230V AC N.O 3A.
This is a Thyristor Based Normally Open 230V Switch that can be turned on / off at a fast rate. This switches at Zero Crossover . Use 5V DC for Best Results.
Three
Phase AC SSR for 1 HP Motor
Notes -
The Termination's of High Current Lines going to Load must be very tight and crimped. Loose contacts will Spark and cause Fire.
Fast Blow Fuse is to be used. Use a 2 Amps Fuse with Holder
in the Hot Line
Read More - Solid State Relays SSR.
Back to Process Control
Applications
...
...
...
...
...
delabs Technologies
30th Aug 2020
...
The documents, software, tools and links are provided to enhance the ability of an electronics student, hobbyist or professional by sharing information. The information, links etc. should be used by the website visitor, at his or her own risk and responsibility. There may be concept, design and link errors in the pages.
Creative Work, ideas and documents of delabs can be used for Product Design and Development by R&D Engineers, Hobbyists, Students and even firms for creating useful products. These cannot be used for reprint, replication or publishing online or offline.