LM331 A to D with Mux Input Switch

This is the full circuit of a V/F convertor interface for 80C31 SBC. The Mux is configured for selecting between two inputs. It uses analog switch 4066. LF353 along with LM331 form the VCO, you can further study such configuration in the Application Notes of TI/NS.

Mixed Circuits Analog with Digital

This design is built above an application note.  Two Pt-100 RTDs are switched to the A/D using the FET Switches.  Here a 1mA Precision current source is shown at the bottom for RTD and a 50mA Current source is shown above for special uses as an example.

LM331 A to D with Mux Input Switch

The Output Fout is a Frequency which is directly proportional to the measured voltage Vin. The pulses can be isolated using opto-couplers to avoid ground loops or electric hazard. An additional protection and scaling circuit at the input may be required for some sensors.

delabs designs – delabs notes

delabs

delabs

Product Design - Industrial Automation and Instrumentation.

You may also like...